Experimental application of optimal depth of PVDs determination under vacuum loading condition

  • Võ Đại Nhật
  • Lâm Hoàng Quốc Việt
  • Phạm Minh Tuấn

Abstract

Viet Nam is one of the country that has a very soft and complicated geological feature. Therefore, how to economize cost but satisfy the standard and technical requirements in designing by selecting an appropriate method in building especially projects constructed on soft ground is always needed to consider and research continuouslly. In this paper, a method how to determine the optimal depth of PVDs under vacuum loading condition for soft ground improvement is presented and applied to specific case in 861 provincial street, Ward Cai Be, Tien Giang District. The soft soil includes two layers with total 12m thick and is allowed to drain on the top and bottom faces (double drainage). The result shows that the optimal depth of PVDs is about 10,5m with the small error of 0,7%

điểm /   đánh giá
Published
2016-07-18
Section
ARTILES