SIMULATION OF LIGHTNING TRANSIENT RESPONSES OF GROUNDING GRID USING FINITE ELEMENT METHOD
Abstract
<!-- /* Font Definitions */ @font-face {font-family:Batang; panose-1:2 3 6 0 0 1 1 1 1 1; mso-font-alt:바탕; mso-font-charset:129; mso-generic-font-family:auto; mso-font-format:other; mso-font-pitch:fixed; mso-font-signature:1 151388160 16 0 524288 0;} @font-face {font-family:"\@Batang"; panose-1:0 0 0 0 0 0 0 0 0 0; mso-font-charset:129; mso-generic-font-family:auto; mso-font-format:other; mso-font-pitch:fixed; mso-font-signature:1 151388160 16 0 524288 0;} /* Style Definitions */ p.MsoNormal, li.MsoNormal, div.MsoNormal {mso-style-parent:""; margin:0in; margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:12.0pt; font-family:"Times New Roman"; mso-fareast-font-family:"Times New Roman";} p.MsoHeader, li.MsoHeader, div.MsoHeader {mso-style-name:"Header\,Header Char Char"; mso-style-link:" Char Char2"; margin:0in; margin-bottom:.0001pt; mso-pagination:widow-orphan; tab-stops:center 3.0in right 6.0in; font-size:12.0pt; font-family:"Times New Roman"; mso-fareast-font-family:"Times New Roman";} span.CharChar2 {mso-style-name:" Char Char2"; mso-style-locked:yes; mso-style-link:"Header\,Header Char Char"; mso-ansi-font-size:12.0pt; mso-bidi-font-size:12.0pt; mso-ansi-language:EN-US; mso-fareast-language:EN-US; mso-bidi-language:AR-SA;} p.Char, li.Char, div.Char {mso-style-name:" Char"; mso-style-link:"Default Paragraph Font"; mso-margin-top-alt:auto; margin-right:0in; mso-margin-bottom-alt:auto; margin-left:0in; text-align:justify; text-indent:.5in; line-height:18.0pt; mso-line-height-rule:exactly; mso-pagination:widow-orphan; font-size:11.0pt; font-family:Arial; mso-fareast-font-family:"Times New Roman";} @page Section1 {size:8.5in 11.0in; margin:1.0in 1.25in 1.0in 1.25in; mso-header-margin:.5in; mso-footer-margin:.5in; mso-paper-source:0;} div.Section1 {page:Section1;} --> This paper presents the application of the Finite Element methods to calculating and modeling the lightning transient responses on grounding grid. The uniform and optimized grids are used in this work. The tested results obtained on many different models of the conductor and grids have seen the effectiveness of the proposed method and the influence of conductor compression to the transient values when the lightning current into the grid at the different positions.
điểm /
đánh giá
Published
2010-08-24
Issue
Section
ARTILES
Copyright belongs to VNU-HCM “Science and Technology Development” Journal. Any copy or reprinting of any form must be permitted by the Journal.