Investigation of the ozone pollution level in some photocopy enterprises and method of treatment

  • Tô Thị Hiền
  • Lại Thùy Hạnh

Abstract

This study measured the ozone pollution level in 4 photocopy shops in Ho Chi Minh City during 2 months, from March to April 2010. The result indicated that ozone concentration increases rapidly when the photocopiers start. The highest concentration of ozone is seemed to be from 11h30 to 16h30 every day. The concentration at the entrance is lower than at the center of the photocopy enterprise. Besides, this study also evaluated the ozone absorption rates of Epipremnum Aureum plant by a hermetic model. The result showed that the absorption rates increase by time, reach to 78.9% after 3 days. Consequently, we can use this plant to reduce the high ozone concentration in the photocopy shops.

điểm /   đánh giá
Published
2012-12-07
Section
ARTILES