Comparison of slug test methods to determine conductivity of Holocen aquifer, Dan Phuong area

  • Thao Bach Nguyen
Keywords: Dan Phuong, Hydraulics conductivity, Porous aquifer, PST, Slug test experiments.

Abstract

Two different slug test methods including: i) slug test using the standard slug rod and ii) pneumatic slug test are conducted in different well/depth in Danphuong field site for a comparative analysis. These methods are examined at least 3 times for each well to estimate hydraulic conductivities by using Hvorslev. The results show correlation between two slug test methods is very hight with R2 = 0,93. Slug tests methods have several advantages and also disadvantage compare to each other. Practical considerations of performing the tests in real life settings are also considered in the method comparison. The slug-rod method meets 7/10 criterions while pneumatic slug test satisfy 8/10 criterions.

điểm /   đánh giá
Published
2021-03-10
Section
Bài viết