Low strength effluent treatment with cyclic technologies in Vietnam
Abstract
Wastewater with low pollution concentrations are common in cities of the developing countries also in Vietnam because sewer network for wastewater is not yet construction that rely on combined sewer network. The results of the decomposition of organic matter partly in combined sewer network significantly reduced levels of BOD, while reducing nitrogen only a small part. The imbalance of BOD, nitrogen ratio is a challenge for treatment of wastewater - especially to ensure the nitrogen meets requirements. Results of the analysis of influent and effluent concentrations in Yen So (Hanoi), Vinh (Nghe An) wastewater treatment plants where applied cyclic activated sludge technologies base on sequencing batch reactors, with good control of operation to show that the effluent quality is stability and meet Vietnamese standard.
điểm /
đánh giá
Published
2016-01-05
Issue
Section
SCIENTIFIC ARTICLE