METHOD DEVELOPMENT FOR ANALYSIS PENTACHLOROBENZENE AND HEXACHLOROBUTADIENE IN WASTEWATER BY GC/MS

  • Nguyen Kim Thuy, Le Bao Hung, Nguyen Thanh Tuan ,Nguyen Thi Thu Hang, Nguyen Thi Nang,Dang Minh Quan, Vu Minh Chau

Tóm tắt

This research presents the optimization of Pentachlorobenzene (PeCB) and Hexachlorobutadiene (HCBD) analysis in surface water. The study investigates the operating parameters of the GC/MS system and the clean-up, enrichment procedures based on liquid-liquid extraction using surrogate standard (Phenanthrene-D10). The calibration curve demonstrated a strong linear correlation (~0.994) within the concentration range of 25 - 600µg/L. The method detection limits were 0.008µg/L for PeCB and 0.004µg/L for HCBD. The recovery of the analytical procedure ranged from 85% to 114%. The method was applied to waste water samples showed good repeatability.

điểm /   đánh giá
Phát hành ngày
2026-01-13
Chuyên mục
KHOA HỌC-CÔNG NGHỆ