Pile capacity from pile dynamic analysis (PDA) and result of testing pile under static compressive load

  • BÙI TRƯỜNG SƠN
  • PHẠM CAO HUYÊN

Abstract

    Evaluation of pile capacity in-situ is an important and necessary work after pile installation in order to conclude the exactly pile bearing capacity in actual conditions. Pile dynamic analysis (PDA) allows determining pile capacity more reliable in short term. In addition, PDA can be able to carry out in cases sort of building site and so large of testing load or when the tested load is underestimating. The main content of the paper is evaluation of PDA models in order to heighten reliability, to analyze input parameters and reliability of PDA in geological conditions of the area.

điểm /   đánh giá
Published
2017-06-26
Section
SCIENTIFIC ARTICLE