BUILTDING THE SURVEYING CONTROL NETWORK OF BA XUYEN COMMUNE, SONG CONG CITY, THAI NGUYEN PROVINCE BY GPS TECHNOLOGY

  • Nguyễn Ngọc Anh

Abstract

The grid control system of Ba Xuyen commune was built using GPS technology with a total of 80 points including: 75 newly established points and 05 original points (092538, 092543, SC-10, SC-16, SC-24) arranged with triangle shape. The results of handling and calculating the adjustment to meet the technical requirements according to current regulations: The maximum error of the central position of the position: (ĐV1-74) = 0.009 m; The greatest medium edge relative error (DV1-18 --- ĐV1-19): mS/S = 1/26,290; The closed error is relative to the largest triangle: (DV1-25 - DV1-26 - ĐV1-27) = 1/11,665. Thus, the control network of Ba Xuyen commune is ensured with high quality, high accuracy, and density of guaranteed points for detailed measurement of cadastral maps of communes.